Wilsonart Fire Rated Laminate

Wilsonart Fire Rated Laminate

Wilsonart International
2400 Wilson Place
P.O. Box 6110
Temple, TX 76503
Website: www.wilsonartlaminate.com

Types 604,605,607
Sheet Sizes: 48x96 or 48x120

Test data for code compliance is from the UL 723 Tunnel Test method. This procedure has been cataloged under the following designations:

American Society for Testing Materials ASTM E 84

American Society for Testing Materials ASTM E 162

American Society for Testing Materials ASTM E 662

American National Standards Institute ANSI No. 2.5

National Fire Protection AgencyNFPA No. 255

Underwriters Laboratories, Inc. UL No. 723

Model Code Designations used to determine flame spread classification


Flame Spread Classification

(Maximum Rating)

International

(IBC)

Life Safety

(NFPA 101)

25

A

A

75

B

B

200

C

C


Ebony Fusin-1799
Shale Moonstone-13045

Brief Description: primarily used in commercial places with casework and cabinetry, wainscoating, interior doors, wall panel and divider systems. Used in airports, hotels, office buildings. Recommended for interior usage. Cannot be put in direct sunlight. Not for direct covering on plaster, concrete walls, or gypsum wallboard.

Composition: has fire retardant adhesives and substrates, melamine resin-treated decorative surface papers, special kraft core sheets (used to obtain the desired thickness). All impregnated with phenolic resin. Comes in most Standard Line (DG1) patterns.